An efficient and sustainable solution to achieve a static ventilation circuit for industrial buildings
The roofing vent is a solution designed from a folded steel sheet structure that allows a constant flow of air without letting water through. The roofing vent is placed in the highest part of the industrial building, or ridge and its operation is based on the difference in atmospheric pressure.
Roofing vent sketch
How does the roofing vent work?
In such a way that the stale air inside the industrial building -warm air, which is not very dense and weighs less than cold air- will move towards the upper part of the building as the renewed air enters through the lower level.Then the roofing vent - installed in the upper part of the building - will allow this heavier air to be extracted through its throat:
Static ventilation circuit operation
Roofing vent applications
The roofing vent is a ventilation solution that is commonly applied in new industrial buildings due to its quick installation and its effectiveness right out of the box. This static fan is perfectly aligned with the principles of sustainability and efficiency since it has zero energy consumption and does not require any maintenance.
Available models of the roofing vent
AIR-TAS 250: Roofing vent with 250 mm throat. It is the most common and is supplied either assembled for quick installation, or unassembled in parts. In this case, it includes an assembly guide.
AIR-TAS 250
AIR-TAS 500: Roofing vent with 500 mm throat. It is typically used for industrial buildings that are larger than average in size and have a high need for indoor air ventilation. This model can also be supplied both assembled and unassembled in parts, with its corresponding assembly guide.
AIR-TAS 500
AIR-TAS 1000: Roofing vent with 1,000 mm throat. It is usually used less commonly for industrial buildings that require an average extraction flow of between 3,000 and 4,000 m^3 per hour per linear meter. In this case, it is only supplied by parts without the possibility of being assembled in the factory.
AIR-TAS 1200: Roofing vent with 1,200 mm throat. Once again, an unusual model designed for industrial spaces in which the activity that takes place inside is very aggressive and requires constant and abundant air circulation. This model must be assembled on site.
AIR-TAS 1200
AIR-TAS 3000: Roofing vent with 3,000 mm throat. With this model, a minimum extraction flow of more than 8,000 m^3 per hour and per linear meter is achieved. It is used in exceptional projects and its installation requires a high knowledge of the solution as well as qualified and experienced personnel in its assembly.
AIR-TAS 3000
The TAS roofing vent includes an anti-bird mesh on its surface to prevent the entry of birds and can be installed on both a simple sheet metal or sandwich panel roof without inconvenience.
TAS roofing vent- anti bird mesh
Static ventilation experts
At TAS, we have been manufacturing these types of solutions for static ventilation for more than 15 years and we can manufacture static fans in more than 20 different colors. If you need additional information or require advice to determine the ventilation needs of an industrial warehouse, do not hesitate to contact us to receive the best solution.
Unassembled roofing vent installation
To end this entry, we would like to leave you with a very interesting video about the installation of an unassembled roofing vent on the roof of an industrial warehouse:
Compartir
Contacta con nuestros técnicos para más información sobre nuestros productos y servcios.
Do not miss this article published by Ecoconstruccion magazine on the latest architectural facade project where TAS has participated We are very happy to announce that the magazine Ecoconstruction in its montly publication has collected the details of the project in which we participated last year 2022 with the supply of more than 15,000 m2 […]
Discover in this post what type of paint your metallic facade should have That's how it is! As you already know, the salinity of the sea is very aggressive against most of the materials that are used. At TAS we know how important this is and when to use solutions that are prepared for these […]
Discover the solution offered by TAS for this translucent metal parapet project installed on a metallic facade This office building needed a translucent parapet for the window of the front metallic facade. Specifically, it had to be a durable material, with minimal maintenance, and keeping the aesthetics and elegance of the facade. Architectural steel solutions […]
Architectural profile recently developed - don't miss it out! We bring you news about an architectural facade profile that we have recently developed and that we love: It is the Cabrera Facade Profile. Some of its main features are: It has up to 25 bends and has a wide range of dimensions with angles and […]
Learn more about the different modulating options offered by this new metal facade profile. Without a doubt, the most versatile profile ever designed. TAS is defined by the flexibility of its production process and by its innovative and avant-garde spirit. For this reason, at TAS we are pleased to be able to launch the Mallorca […]
This colorful facade matches its location, San Juan de Alicante, where the exterior facade of the Carrefour shopping center has been completely renovated, using a composite panel resource together with these perforated and post-lacquered steel trays. One of the latest projects in which TAS has participated with the supply of its Architectural Tray has been […]
How far do you think we can go to meet the demands of our customers in the manufacture of customized decorative sheets for metallic facades? We recently received a query about our Menorca profile, as it was the architectural profile chosen for a decorative border on the main facade of a residential building. Both the […]
If you have come this far, you probably know what a ventilated facade consists of. However, we will start by reviewing the concept: The metallic ventilated facade is an increasingly used constructive solution whose ultimate goal is the elimination of the thermal bridge to generate excellent insulation between the external conditions and the interior of […]
Sandwich sheet and sandwich panel are terms used in the construction and engineering industry to describe composite structures. Although both terms refer to internal and external skin panel systems, there are some differences between them. The sandwich sheet refers to a type of structure composed of two rigid external layers (usually metal) with an intermediate […]
The Plaza Europa office tower wich stands amongst the heights of Barcelona is a 22 storey building with an outstanding aluminium facade, provided by TAS . This construction has been built under the principles of sustainability , which would mean a leed Platinum certification. Conception of an aluminum and glass facade This 22-story tower designed […]
This website uses cookies so that we can provide you with the best possible user experience. Cookie information is stored in your browser and performs functions such as recognising you when you return to our site or helping our team understand which parts of the site you find most interesting and useful.
Strictly necessary cookies
Strictly necessary cookies must always be enabled so that we can save your cookie settings preferences.
If you disable this cookie we will not be able to save your preferences. This means that each time you visit this website you will have to enable or disable cookies again.
Third party cookies
This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, or the most popular pages.
Leaving this cookie active allows us to improve our website.
Please enable strictly necessary cookies first so that we can save your preferences!